| Weight | N/A |
|---|---|
| Features | |
| Paints | |
| Size | |
| Colors |
Stabilis E-ZP
RM52.50 – RM218.75Price range: RM52.50 through RM218.75
Stabilis E-ZP is a high solid, surface tolerant pure epoxy zinc phosphate coating that provides excellent durability in even the most corrosive environments.
[ht-ctc-chat call_to_action="Whatsapp Enquiry" pre_filled="Hello ,I would like to inquire on {{url}}" style=8]
- Additional information
- Description
- Features
- Typical Uses
- Physical Data
- Application Data
- Application Procedure
- Condition of Application
- Surface Preparation
- Performance Data
- Safety Precaution & Clean-Up
- Disclaimer & Limited Warranty
- Need Help?
- Reviews (0)
Description
Looking for a reliable and easy-to-use primer for your ship or coastal steel structures? Look no further than Stabilis E-ZP! This high-solid, surface-tolerant pure epoxy zinc phosphate coating provides excellent durability in even the most corrosive environments. It can be applied via spray, brush, or roller, making it perfect for a variety of applications. Additionally, it is compatible with various subsequent coatings, making it truly versatile. Whether you are looking to protect hulls, decks, superstructure, or ballast tanks, Stabilis E-ZP is the perfect choice for you!
Features
- Excellent durability in a wide range of corrosives. Meet the corrosive requirement of ISO12944-6 C5I or C5M as a system.
- Easy to use – spray, brush, roller
- General purpose Surface Tolerant Epoxy Primer.
- Suitable for most areas of the ship and coastal steel structures.
- Excellent mechanical and physical properties for heavy-duty application
- Compatible with various subsequent coating
Typical Uses
Suitable for use as a protective coating for various parts of the ship such as hull, deck, superstructures, and ballast tanks. Recommend to use for steel structures in coastal areas such as refineries, mining facilities, power plants, bridges, buildings and steel installation. It has excellent mechanical and physical properties such as adhesion, impact, and abrasion resistance which minimize mechanical damage during handling and transportation.
Physical Data
| Color | : | Light Grey, grey, Red Brown, Black, Buff |
| Flash Points | : | Base : 15.0 0C Hardener : 14.0 0C |
| Volume Solid | : | 76+/- 2% |
| VOC(as supplied) | : | 256g/L |
| Shelf Life @250C / indoor | : | 24 months |
Typical Thickness: 75 ~ 150m dried film.
Application Data
Mixing ratio : Base : hardener = 90 : 10 ( by weight)
Application Method: airless spray, roller, brush
| Mixing Procedure : | Add part B to part A and power mix for at least two minutes or until homogeneous. |
| Drying schedule : | Drying by solvent evaporation and chemical cross-linking. Higher film thickness, insufficient ventilation, or lower temperature will require longer drying time. Excessive humidity or condensation on the surface can interfere with the drying cause discoloration and may result in a surface haze. Any haze or contamination must be removed by water washing before recoating. |
This product requires the substrate temperature to be above the dew point ( + 3~5 0 C). Condensation due to substrate temperatures below dew point can cause flash rust on metal and adhesion will be affected.
Color Different: The paint used as a primer or anti-fouling may have slight color variance between batches. Similarly, the paint under sunlight exposure may fade and chalk.
Application Procedure
Mix properly the paint before use.
- Flush equipment with epoxy thinner before use.
- Mix the paint (part A and Part B accordingly to the mixing ratio) thoroughly until homogeneous.
- Thin with epoxy thinner only if necessary for workability.
- When applying by conventional spray, use adequate air pressure and volume for proper atomization.
- Apply a wet coat in even parallel passes, overlapping 50% to avoid holidays and pinholes.
- Excessive thickness can prolong drying and sagging.
- Clean up all equipment with thinner immediately after use.
- Keep containers tightly close and store them in the proper storage area.
Condition of Application
Use a brush or roller with a 1/8″ nap. Apply at the sufficient thickness and avoid repeating rolling to have good leveling.
| Temperature | : | Min 5 0 C ; Max 50 0 C | ||
| Humidity | : | Maximum 85 % R.H. | ||
| For Airless spray:- | ||||
| Tip Size | : | Graco 619, 623 or equivalent | ||
| Paint Output pressure | : | 14.7 – 17.7 MPa (g) | ||
| Viscosity | : | 1.5 ~ 2.0 Pa.s | ||
| Thinning | : | 0 – 10 % by volume | ||
Surface Preparation
| General : |
| Surfaces must be clean and dry, and all contaminants like dirt, dust, and oil must be removed by appropriate methods to ensure good adhesion.
|
| Abrasive blast clean: |
| Abrasive blast clean to Sa 2.5 (ISO-8501) or SSPC-SP6. In case of hydro blasting or hydro jetting to remove the existing coating, ginger rust should be removed and blow dry before application. The surface profile must be a minimum of 50 microns.
|
| Shop primed steelwork: |
| The Weld seam and the damaged area should be cleaned to a minimum St3 or SSPC-SP3. The shop-primed steelwork should be repaired for any rust and free from any contaminant with suitable secondary surface preparation such as spot blasts, sweeping, or power tooling.
|
Performance Data
| Properties | Test Method | Evaluation |
| Pull off Strength | ASTM D4541-02 | > 20kgf /cm2 ( 2Mpa) |
| Salt Spray ( 5% NaCl solution) |
ASTM B117 | 1500hrs, passed C5M, as system |
| Humidity (50 0C, 100% RH) |
ASTM D1748 | 1000hrs, passed C5M, as system |
Safety Precaution & Clean-Up
|
Safety : |
Read and follow the material safety data sheet (MSDS) before use. Employ normal safety precautions. Put on necessary personal protection equipment when handling and using this product. |
| Ventilation : | when working in a confined workplace, thorough air ventilation must be used during and after application until the coating is cured. The ventilation system should be effective to prevent solvent vapor concentration from reaching a lower explosion limit for the product and to ensure exposure limit to the personnel is below the permissible exposure limit. |
| Caution : | All electrical equipment and installations should be made and properly grounded. In areas where explosion hazards exist, workmen should be used non-ferrous tools and conductive and non-sparkling shoes. |
| Clean-up : | Use Hana Paint polyurethane thinner (Hana Thinner U) or hydrocarbon solvent for cleaning. Observe safety precautions when using the solvents. In case of spillage, absorb and dispose of the material and used container according to local required regulations or through a licensed waste collector. |
Disclaimer & Limited Warranty
Disclaimer
Data, specifications, directions, and recommendations given in this data sheet represent test results or experience obtained under controlled or specially defined circumstances. Their accuracy, completeness, or appropriateness under the actual conditions of any intended use is not guaranteed and must be determined by the user. The products are delivered and any technical assistance is given subject to our GENERAL CONDITIONS OF SALE, DELIVERY, AND SERVICE and, unless otherwise expressly agreed in writing, manufacturer and seller assume no liability in excess of that stated therein for results obtained, injury, direct or consequential damage incurred from the use as recommended above or otherwise.
Limited Warranty
Whilst we endeavor to ensure that all advice we give about this product is correct and manufactured according to the standard quality control system, however, we have no control over either the quality or condition of the substrate or many other factors affecting the use and application of the product. Therefore, unless we specifically agree in writing to do so, we do not accept any liability whatsoever or howsoever arising for the performance of the product or for any loss or damage arising out of the use of this product.
Need Help?
Send Us An Email
Contact us at info@awatrahana.com or call us at +60143989049 for questions related to this products or send us a form via the contact form below.
Be the first to review “Stabilis E-ZP” Cancel reply
You must be logged in to post a review.
Related products
Stabilis
Stabilis DTM A is a self-priming epoxy acrylic coating that can be used as direct to metal primer and top coat.
This product has multiple variants. The options may be chosen on the product pageStabilis
STABILIS EP-GARD GF is a high-build epoxy coating that is reinforced with glass flakes for exceptional durability.
This product has multiple variants. The options may be chosen on the product pageStabilis
Stabilis ACR is a self-priming acrylic epoxy coating that can be used as both primer and top coat on metal surfaces.
This product has multiple variants. The options may be chosen on the product pageStabilis
HANA STABILIS AF-100 is a high-solid, TBT-free self-polishing anti-fouling paint that uses an advanced leaching control mechanism for long-lasting protection against marine organisms.
This product has multiple variants. The options may be chosen on the product pageStabilis
STABILIS EP-GARD XTRA GF is an epoxy coating that is resistant to a variety of environments, including chemicals, water, salt water, and alkalis.
This product has multiple variants. The options may be chosen on the product pageStabilis
STABILIS E-MIO is a two-component, high solid, surface tolerant pure epoxy micaceous iron oxide coating that can be used as an anti-corrosive primer in severe environments.
Stabilis
STABILIS EP is a two-component, high-solid epoxy primer that can be used in a wide range of corrosive environments.
This product has multiple variants. The options may be chosen on the product pageStabilis
Stabilis S Prime is a lead and chrome free general purpose primer that can be used on a variety of surfaces.
This product has multiple variants. The options may be chosen on the product page









Reviews